Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
Yes
Rated control supply voltage Us at DC
24 - 24V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated operation power at AC-3, 400 V
4kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
10A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current Ie
8.5A
Rail mounting possible
Yes
Overload release current setting
6.3 - 10A
Rated conditional short-circuit current, type 2, 400 V
50000A
With transformer
No
Number of command positions
0
Rated conditional short-circuit current, type 2, 230 V
50000A
Suitable for emergency stop
No
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
External reset possible
No
Supporting protocol for CAN
No
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Supporting protocol for Modbus
No
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for SUCONET
No
Degree of protection (IP)
IP00
Supporting protocol for ASI
No
Supporting protocol for LON
No
Release class
CLASS 10 A
Number of indicator lights
0
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet
No
Supporting protocol for INTERBUS
No
Number of auxiliary contacts as normally open contact
0
Supporting protocol for SERCOS
No
Supporting protocol for PROFIBUS
No
Type of electrical connection of main circuit
Screw connection
With fuse
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Temperature compensated overload protection
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Width
90mm
Supporting protocol for other bus systems
No
Height
123.4mm
Depth
228mm
Degree of protection (NEMA)
Other
Supporting protocol for AS-Interface Safety at Work
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-R-10-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
Rated control supply voltage Us at DC
24 .. 24V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated operation power at AC-3, 400 V
4kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation current at AC-3, 400 V
10A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current Ie
8.5A
Rail mounting possible
Overload release current setting
6.3 .. 10A
Rated conditional short-circuit current, type 2, 400 V
50000A
With transformer
Number of command positions
0
Rated conditional short-circuit current, type 2, 230 V
50000A
Suitable for emergency stop
Ambient temperature, upper operating limit
55°C
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection for auxiliary- and control current circuit
Screw connection
External reset possible
Supporting protocol for CAN
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Supporting protocol for Modbus
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for SUCONET
Degree of protection (IP)
IP00
Supporting protocol for ASI
Supporting protocol for LON
Release class
CLASS 10 A
Number of indicator lights
0
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet
Supporting protocol for INTERBUS
Number of auxiliary contacts as normally open contact
0
Supporting protocol for SERCOS
Supporting protocol for PROFIBUS
Type of electrical connection of main circuit
Screw connection
With fuse
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Temperature compensated overload protection
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Width
90mm
Supporting protocol for other bus systems
Height
123.4mm
Depth
228mm
Degree of protection (NEMA)
Other
Supporting protocol for AS-Interface Safety at Work
From same serie