Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
3kW
Temperature compensated overload protection
Yes
Overload release current setting
8 - 12A
Ambient temperature, upper operating limit
55°C
Power consumption
0.9W
Rated operation current at AC-3, 400 V
12A
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
With fuse
No
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Rated control supply voltage Us at AC 50HZ
0 - 0V
Voltage type for actuating
DC
Supporting protocol for INTERBUS
No
Degree of protection (IP)
IP00
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rail mounting possible
No
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Supporting protocol for PROFIBUS
No
Number of command positions
0
Rated conditional short-circuit current, type 2, 230 V
50000A
With transformer
No
Supporting protocol for LON
No
With short-circuit release
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Data-Highway
No
Release class
CLASS 10 A
Rated control supply voltage Us at AC 60HZ
0 - 0V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation power at AC-3, 400 V
5.5kW
Rated operation current Ie
11.3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for CAN
No
Number of auxiliary contacts as normally open contact
1
Supporting protocol for SERCOS
No
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated control supply voltage Us at DC
24 - 24V
Supporting protocol for EtherNet/IP
No
Supporting protocol for SUCONET
No
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFINET CBA
No
External reset possible
No
Supporting protocol for Modbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Width
45mm
Depth
123.4mm
Height
228mm
Supporting protocol for DeviceNet
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-D-12-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
3kW
Temperature compensated overload protection
Overload release current setting
8 .. 12A
Ambient temperature, upper operating limit
55°C
Power consumption
0.9W
Rated operation current at AC-3, 400 V
12A
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 2
Number of indicator lights
0
With fuse
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Voltage type for actuating
DC
Supporting protocol for INTERBUS
Degree of protection (IP)
IP00
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rail mounting possible
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Supporting protocol for PROFIBUS
Number of command positions
0
Rated conditional short-circuit current, type 2, 230 V
50000A
With transformer
Supporting protocol for LON
With short-circuit release
Supporting protocol for Foundation Fieldbus
Supporting protocol for Data-Highway
Release class
CLASS 10 A
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated operation power at AC-3, 400 V
5.5kW
Rated operation current Ie
11.3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Supporting protocol for CAN
Number of auxiliary contacts as normally open contact
1
Supporting protocol for SERCOS
Number of auxiliary contacts as normally closed contact
0
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for EtherNet/IP
Supporting protocol for SUCONET
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFINET CBA
External reset possible
Supporting protocol for Modbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Width
45mm
Depth
123.4mm
Height
228mm
Supporting protocol for DeviceNet
From same serie