Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated control supply voltage Us at DC
0 - 0V
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
230 - 230V
With short-circuit release
Yes
Rated operation current at AC-3, 400 V
10A
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
8.5A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Power consumption
2.1W
Overload release current setting
6.3 - 10A
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Suitable for emergency stop
No
Temperature compensated overload protection
Yes
Coordination class according to IEC 60947-4-3
Class 2
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
0
With transformer
No
Rail mounting possible
No
External reset possible
No
Degree of protection (IP)
IP00
With fuse
No
Supporting protocol for AS-Interface Safety at Work
No
Number of indicator lights
0
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Height
228mm
Width
45mm
Depth
123.4mm
Supporting protocol for other bus systems
No
Supporting protocol for PROFIBUS
No
Supporting protocol for Data-Highway
No
Degree of protection (NEMA)
Other
Supporting protocol for DeviceNet
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Supporting protocol for SUCONET
No
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-D-10-M17(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at DC
0 .. 0V
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
230 .. 230V
With short-circuit release
Rated operation current at AC-3, 400 V
10A
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
8.5A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Power consumption
2.1W
Overload release current setting
6.3 .. 10A
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10 A
Ambient temperature, upper operating limit
55°C
Suitable for emergency stop
Temperature compensated overload protection
Coordination class according to IEC 60947-4-3
Class 2
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of command positions
0
With transformer
Rail mounting possible
External reset possible
Degree of protection (IP)
IP00
With fuse
Supporting protocol for AS-Interface Safety at Work
Number of indicator lights
0
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Height
228mm
Width
45mm
Depth
123.4mm
Supporting protocol for other bus systems
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Degree of protection (NEMA)
Other
Supporting protocol for DeviceNet
Supporting protocol for TCP/IP
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
From same serie