Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- EATON
Technical specifications
Type of control element
Door coupling rotary drive
Number of poles
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
63A
Motor drive integrated
No
Type of electrical connection of main circuit
Screw connection
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
22kW
Degree of protection (IP), front side
IP65
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Suitable for distribution board installation
No
Degree of protection (NEMA)
Other
Max. rated operation voltage Ue AC
690V
Conditioned rated short-circuit current Iq
2kA
Rated operating voltage
690 - 690V
Rated short-time withstand current lcw
1.3kA
Suitable for front mounting 4-hole
Yes
Version as emergency stop installation
No
Version as reversing switch
No
Voltage release optional
No
Version as maintenance-/service switch
Yes
Interlockable
Yes
Switching power at 400 V
30kW
Number of switches
1
Rated permanent current at AC-23, 400 V
63A
Suitable for front mounting centre
No
Version as main switch
Yes
Version as safety switch
No
Rated operation power at AC-23, 400 V
30kW
Rated permanent current at AC-21, 400 V
63A
Colour control element
Red
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
T5B-3-SOND*/EA/SVB

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- EATON
Technical specifications
Type of control element
Door coupling rotary drive
Number of poles
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
63A
Motor drive integrated
Type of electrical connection of main circuit
Screw connection
Motor drive optional
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
22kW
Degree of protection (IP), front side
IP65
Suitable for floor mounting
Suitable for intermediate mounting
Suitable for distribution board installation
Degree of protection (NEMA)
Other
Max. rated operation voltage Ue AC
690V
Conditioned rated short-circuit current Iq
2kA
Rated operating voltage
690 .. 690V
Rated short-time withstand current lcw
1.3kA
Suitable for front mounting 4-hole
Version as emergency stop installation
Version as reversing switch
Voltage release optional
Version as maintenance-/service switch
Interlockable
Switching power at 400 V
30kW
Number of switches
1
Rated permanent current at AC-23, 400 V
63A
Suitable for front mounting centre
Version as main switch
Version as safety switch
Rated operation power at AC-23, 400 V
30kW
Rated permanent current at AC-21, 400 V
63A
Colour control element
Red
From same serie
Related products
We use cookies to enhance your experience.