Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Number of poles
0
Version as main switch
Yes
Version as emergency stop installation
No
Version as maintenance-/service switch
Yes
Version as safety switch
No
Max. rated operation voltage Ue AC
690V
Number of switches
1
Version as reversing switch
No
Rated operating voltage
690 - 690V
Rated permanent current at AC-23, 400 V
13.3A
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Switching power at 400 V
5.5kW
Rated permanent current Iu
20A
Rated operation power at AC-23, 400 V
5.5kW
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
6kA
Number of auxiliary contacts as normally open contact
0
Rated short-time withstand current lcw
0.32kA
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Motor drive integrated
No
Voltage release optional
No
Suitable for floor mounting
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Yes
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Type of control element
Door coupling rotary drive
Colour control element
Red
Interlockable
Yes
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
No
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Width
65mm
Height
74mm
Depth
101mm
Related products
From same serie
T0-1-SOND*/EA/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Number of poles
0
Version as main switch
Version as emergency stop installation
Version as maintenance-/service switch
Version as safety switch
Max. rated operation voltage Ue AC
690V
Number of switches
1
Version as reversing switch
Rated operating voltage
690 .. 690V
Rated permanent current at AC-23, 400 V
13.3A
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Switching power at 400 V
5.5kW
Rated permanent current Iu
20A
Rated operation power at AC-23, 400 V
5.5kW
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
6kA
Number of auxiliary contacts as normally open contact
0
Rated short-time withstand current lcw
0.32kA
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Motor drive integrated
Voltage release optional
Suitable for floor mounting
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Suitable for front mounting centre
Suitable for distribution board installation
Suitable for intermediate mounting
Type of control element
Door coupling rotary drive
Colour control element
Red
Interlockable
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Width
65mm
Height
74mm
Depth
101mm
From same serie
Related products
We use cookies to enhance your experience.