Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Version as emergency stop installation
No
Rated permanent current Iu
25A
Version as safety switch
No
Rated operation power at AC-3, 400 V
7.5kW
Rated permanent current at AC-23, 400 V
25A
Max. rated operation voltage Ue AC
690V
Version as reversing switch
No
Number of switches
1
Rated permanent current at AC-21, 400 V
25A
Number of auxiliary contacts as normally closed contact
0
Switching power at 400 V
13kW
Conditioned rated short-circuit current Iq
50kA
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Rated operation power at AC-23, 400 V
13kW
Suitable for floor mounting
Yes
Motor drive integrated
No
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Device construction
Complete device in housing
Suitable for distribution board installation
No
Interlockable
Yes
Type of control element
Door coupling rotary drive
Suitable for intermediate mounting
No
Suitable for front mounting centre
No
Colour control element
Black
With pre-assembled cabling
No
Type of electrical connection of main circuit
Screw connection
Rated short-time withstand current lcw
0.64kA
Degree of protection (IP), front side
IP65
Motor drive optional
No
Rated operating voltage
690 - 690V
Suitable for front mounting 4-hole
No
Degree of protection (NEMA)
12
Width
80mm
Height
137mm
Depth
115mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
P1-25/I1/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Version as main switch
Version as emergency stop installation
Rated permanent current Iu
25A
Version as safety switch
Rated operation power at AC-3, 400 V
7.5kW
Rated permanent current at AC-23, 400 V
25A
Max. rated operation voltage Ue AC
690V
Version as reversing switch
Number of switches
1
Rated permanent current at AC-21, 400 V
25A
Number of auxiliary contacts as normally closed contact
0
Switching power at 400 V
13kW
Conditioned rated short-circuit current Iq
50kA
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Rated operation power at AC-23, 400 V
13kW
Suitable for floor mounting
Motor drive integrated
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Device construction
Complete device in housing
Suitable for distribution board installation
Interlockable
Type of control element
Door coupling rotary drive
Suitable for intermediate mounting
Suitable for front mounting centre
Colour control element
Black
With pre-assembled cabling
Type of electrical connection of main circuit
Screw connection
Rated short-time withstand current lcw
0.64kA
Degree of protection (IP), front side
IP65
Motor drive optional
Rated operating voltage
690 .. 690V
Suitable for front mounting 4-hole
Degree of protection (NEMA)
12
Width
80mm
Height
137mm
Depth
115mm