Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Yes
Version as emergency stop installation
Yes
Version as main switch
Yes
Rated permanent current at AC-21, 400 V
32A
Rated permanent current Iu
32A
Version as reversing switch
No
Number of switches
1
Version as safety switch
No
Rated permanent current at AC-23, 400 V
32A
Rated operation power at AC-3, 400 V
11kW
Rated operating voltage
690 - 690V
Rated short-time withstand current lcw
0.65kA
Rated operation power at AC-23, 400 V
15kW
Switching power at 400 V
15kW
Conditioned rated short-circuit current Iq
1kA
Number of poles
4
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Motor drive optional
No
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Type of control element
Door coupling rotary drive
Suitable for intermediate mounting
No
Suitable for front mounting 4-hole
No
With pre-assembled cabling
No
Suitable for front mounting centre
Yes
Interlockable
Yes
Degree of protection (IP), front side
IP65
Suitable for distribution board installation
No
Type of electrical connection of main circuit
Screw connection
Degree of protection (NEMA)
12
Height
74mm
Width
65mm
Depth
127mm
Colour control element
Red
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
T3-3-8901/EA/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Version as emergency stop installation
Version as main switch
Rated permanent current at AC-21, 400 V
32A
Rated permanent current Iu
32A
Version as reversing switch
Number of switches
1
Version as safety switch
Rated permanent current at AC-23, 400 V
32A
Rated operation power at AC-3, 400 V
11kW
Rated operating voltage
690 .. 690V
Rated short-time withstand current lcw
0.65kA
Rated operation power at AC-23, 400 V
15kW
Switching power at 400 V
15kW
Conditioned rated short-circuit current Iq
1kA
Number of poles
4
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Type of control element
Door coupling rotary drive
Suitable for intermediate mounting
Suitable for front mounting 4-hole
With pre-assembled cabling
Suitable for front mounting centre
Interlockable
Degree of protection (IP), front side
IP65
Suitable for distribution board installation
Type of electrical connection of main circuit
Screw connection
Degree of protection (NEMA)
12
Height
74mm
Width
65mm
Depth
127mm
Colour control element
Red
From same serie