Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current at AC-23, 400 V
13.3A
Version as emergency stop installation
No
Version as safety switch
No
Number of switches
1
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
No
Version as main switch
No
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current Iu
20A
Rated permanent current at AC-21, 400 V
20A
Conditioned rated short-circuit current Iq
6kA
Rated operating voltage
690 - 690V
Rated operation power at AC-23, 400 V
5.5kW
Motor drive optional
No
Number of auxiliary contacts as normally closed contact
0
Switching power at 400 V
5.5kW
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Yes
Number of auxiliary contacts as normally open contact
0
Suitable for intermediate mounting
Yes
Voltage release optional
No
Version as reversing switch
No
Suitable for front mounting 4-hole
No
Degree of protection (IP), front side
IP00
Suitable for distribution board installation
No
Degree of protection (NEMA)
Other
Motor drive integrated
No
Colour control element
Black
Interlockable
No
Number of poles
4
Rated short-time withstand current lcw
0.32kA
With pre-assembled cabling
No
Type of control element
Short thumb-grip
Type of electrical connection of main circuit
Screw connection
Suitable for front mounting centre
No
Number of auxiliary contacts as change-over contact
0
Width
48mm
Depth
58mm
Height
8mm
From same serie
T0-2-8900/XZ

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current at AC-23, 400 V
13.3A
Version as emergency stop installation
Version as safety switch
Number of switches
1
Max. rated operation voltage Ue AC
690V
Version as maintenance-/service switch
Version as main switch
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current Iu
20A
Rated permanent current at AC-21, 400 V
20A
Conditioned rated short-circuit current Iq
6kA
Rated operating voltage
690 .. 690V
Rated operation power at AC-23, 400 V
5.5kW
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Switching power at 400 V
5.5kW
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Number of auxiliary contacts as normally open contact
0
Suitable for intermediate mounting
Voltage release optional
Version as reversing switch
Suitable for front mounting 4-hole
Degree of protection (IP), front side
IP00
Suitable for distribution board installation
Degree of protection (NEMA)
Other
Motor drive integrated
Colour control element
Black
Interlockable
Number of poles
4
Rated short-time withstand current lcw
0.32kA
With pre-assembled cabling
Type of control element
Short thumb-grip
Type of electrical connection of main circuit
Screw connection
Suitable for front mounting centre
Number of auxiliary contacts as change-over contact
0
Width
48mm
Depth
58mm
Height
8mm
From same serie