Technical specifications
Number of poles
0
Max. rated operation voltage Ue AC
690V
Version as main switch
Yes
Rated short-time withstand current lcw
1.7kA
Conditioned rated short-circuit current Iq
2kA
Switching power at 400 V
55kW
Version as reversing switch
No
Version as maintenance-/service switch
Yes
Version as safety switch
No
Rated operation power at AC-23, 400 V
55kW
Motor drive optional
No
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
30kW
Version as emergency stop installation
No
Suitable for floor mounting
Yes
Number of switches
1
Rated operating voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-21, 400 V
100A
Motor drive integrated
No
Rated permanent current Iu
100A
Number of auxiliary contacts as normally closed contact
0
Voltage release optional
No
Rated permanent current at AC-23, 400 V
100A
Device construction
Complete device in housing
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Colour control element
Red
Interlockable
Yes
Type of control element
Door coupling rotary drive
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Height
204mm
With pre-assembled cabling
No
Depth
280mm
Width
200mm
Degree of protection (NEMA)
12
Related products
From same serie
T5-3-SOND*/I5/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Number of poles
0
Max. rated operation voltage Ue AC
690V
Version as main switch
Rated short-time withstand current lcw
1.7kA
Conditioned rated short-circuit current Iq
2kA
Switching power at 400 V
55kW
Version as reversing switch
Version as maintenance-/service switch
Version as safety switch
Rated operation power at AC-23, 400 V
55kW
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
30kW
Version as emergency stop installation
Suitable for floor mounting
Number of switches
1
Rated operating voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-21, 400 V
100A
Motor drive integrated
Rated permanent current Iu
100A
Number of auxiliary contacts as normally closed contact
0
Voltage release optional
Rated permanent current at AC-23, 400 V
100A
Device construction
Complete device in housing
Suitable for distribution board installation
Suitable for intermediate mounting
Suitable for front mounting centre
Suitable for front mounting 4-hole
Colour control element
Red
Interlockable
Type of control element
Door coupling rotary drive
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP), front side
IP65
Height
204mm
With pre-assembled cabling
Depth
280mm
Width
200mm
Degree of protection (NEMA)
12