Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as main switch
No
Version as reversing switch
No
Rated permanent current Iu
32A
Version as safety switch
No
Rated permanent current at AC-23, 400 V
32A
Rated operating voltage
690 - 690V
Rated permanent current at AC-21, 400 V
32A
Rated operation power at AC-3, 400 V
11kW
Switching power at 400 V
15kW
Rated short-time withstand current lcw
0.65kA
Conditioned rated short-circuit current Iq
1kA
Version as maintenance-/service switch
No
Rated operation power at AC-23, 400 V
15kW
Version as emergency stop installation
No
Number of switches
1
Number of auxiliary contacts as normally closed contact
1
Number of poles
6
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Suitable for front mounting 4-hole
No
Suitable for floor mounting
Yes
Motor drive integrated
No
Colour control element
Black
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Voltage release optional
No
Type of electrical connection of main circuit
Screw connection
Device construction
Complete device in housing
With pre-assembled cabling
No
Suitable for front mounting centre
No
Degree of protection (IP), front side
IP65
Interlockable
No
Type of control element
Short thumb-grip
Number of auxiliary contacts as normally open contact
1
Width
100mm
Degree of protection (NEMA)
12
Height
127mm
Depth
181mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
T3-4-15682/I2

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as main switch
Version as reversing switch
Rated permanent current Iu
32A
Version as safety switch
Rated permanent current at AC-23, 400 V
32A
Rated operating voltage
690 .. 690V
Rated permanent current at AC-21, 400 V
32A
Rated operation power at AC-3, 400 V
11kW
Switching power at 400 V
15kW
Rated short-time withstand current lcw
0.65kA
Conditioned rated short-circuit current Iq
1kA
Version as maintenance-/service switch
Rated operation power at AC-23, 400 V
15kW
Version as emergency stop installation
Number of switches
1
Number of auxiliary contacts as normally closed contact
1
Number of poles
6
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Suitable for front mounting 4-hole
Suitable for floor mounting
Motor drive integrated
Colour control element
Black
Suitable for distribution board installation
Suitable for intermediate mounting
Voltage release optional
Type of electrical connection of main circuit
Screw connection
Device construction
Complete device in housing
With pre-assembled cabling
Suitable for front mounting centre
Degree of protection (IP), front side
IP65
Interlockable
Type of control element
Short thumb-grip
Number of auxiliary contacts as normally open contact
1
Width
100mm
Degree of protection (NEMA)
12
Height
127mm
Depth
181mm
From same serie
Related products