Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Yes
Version as main switch
Yes
Version as safety switch
No
Rated operating voltage
690 - 690V
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
13.3A
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
20A
Number of switches
1
Version as reversing switch
No
Rated permanent current at AC-21, 400 V
20A
Number of poles
4
Rated operation power at AC-23, 400 V
5.5kW
Motor drive optional
No
Version as emergency stop installation
Yes
Conditioned rated short-circuit current Iq
6kA
Switching power at 400 V
5.5kW
Number of auxiliary contacts as normally open contact
1
Rated short-time withstand current lcw
0.32kA
Voltage release optional
No
Motor drive integrated
No
Rated operation power at AC-3, 400 V
5.5kW
Number of auxiliary contacts as normally closed contact
1
Device construction
Complete device in housing
Suitable for distribution board installation
No
Suitable for floor mounting
Yes
Suitable for front mounting centre
No
Suitable for intermediate mounting
No
Suitable for front mounting 4-hole
No
Degree of protection (NEMA)
12
With pre-assembled cabling
No
Width
80mm
Height
130mm
Depth
137mm
Colour control element
Red
Interlockable
Yes
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Type of control element
Door coupling rotary drive
From same serie
T0-3-15681/I1/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as maintenance-/service switch
Version as main switch
Version as safety switch
Rated operating voltage
690 .. 690V
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
13.3A
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
20A
Number of switches
1
Version as reversing switch
Rated permanent current at AC-21, 400 V
20A
Number of poles
4
Rated operation power at AC-23, 400 V
5.5kW
Motor drive optional
Version as emergency stop installation
Conditioned rated short-circuit current Iq
6kA
Switching power at 400 V
5.5kW
Number of auxiliary contacts as normally open contact
1
Rated short-time withstand current lcw
0.32kA
Voltage release optional
Motor drive integrated
Rated operation power at AC-3, 400 V
5.5kW
Number of auxiliary contacts as normally closed contact
1
Device construction
Complete device in housing
Suitable for distribution board installation
Suitable for floor mounting
Suitable for front mounting centre
Suitable for intermediate mounting
Suitable for front mounting 4-hole
Degree of protection (NEMA)
12
With pre-assembled cabling
Width
80mm
Height
130mm
Depth
137mm
Colour control element
Red
Interlockable
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Type of control element
Door coupling rotary drive
From same serie
We use cookies to enhance your experience.