Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current at AC-23, 400 V
13.3A
Version as safety switch
No
Version as main switch
No
Version as emergency stop installation
No
Number of switches
1
Version as maintenance-/service switch
No
Rated short-time withstand current lcw
0.32kA
Version as reversing switch
No
Rated operating voltage
690 - 690V
Rated permanent current Iu
20A
Max. rated operation voltage Ue AC
690V
Conditioned rated short-circuit current Iq
6kA
Rated operation power at AC-3, 400 V
5.5kW
Rated operation power at AC-23, 400 V
5.5kW
Number of auxiliary contacts as normally closed contact
1
Switching power at 400 V
5.5kW
Number of poles
4
Rated permanent current at AC-21, 400 V
20A
Number of auxiliary contacts as normally open contact
1
Motor drive optional
No
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
No
Suitable for front mounting 4-hole
Yes
Suitable for front mounting centre
No
Suitable for intermediate mounting
No
Degree of protection (IP), front side
IP65
Suitable for distribution board installation
No
Colour control element
Black
Interlockable
No
Type of electrical connection of main circuit
Screw connection
Width
48mm
Depth
95mm
With pre-assembled cabling
No
Height
48mm
Type of control element
Short thumb-grip
Degree of protection (NEMA)
12
From same serie
T0-3-15680/E

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current at AC-23, 400 V
13.3A
Version as safety switch
Version as main switch
Version as emergency stop installation
Number of switches
1
Version as maintenance-/service switch
Rated short-time withstand current lcw
0.32kA
Version as reversing switch
Rated operating voltage
690 .. 690V
Rated permanent current Iu
20A
Max. rated operation voltage Ue AC
690V
Conditioned rated short-circuit current Iq
6kA
Rated operation power at AC-3, 400 V
5.5kW
Rated operation power at AC-23, 400 V
5.5kW
Number of auxiliary contacts as normally closed contact
1
Switching power at 400 V
5.5kW
Number of poles
4
Rated permanent current at AC-21, 400 V
20A
Number of auxiliary contacts as normally open contact
1
Motor drive optional
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for front mounting centre
Suitable for intermediate mounting
Degree of protection (IP), front side
IP65
Suitable for distribution board installation
Colour control element
Black
Interlockable
Type of electrical connection of main circuit
Screw connection
Width
48mm
Depth
95mm
With pre-assembled cabling
Height
48mm
Type of control element
Short thumb-grip
Degree of protection (NEMA)
12
From same serie