Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
100A
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Rated permanent current Iu
100A
Version as safety switch
No
Version as main switch
Yes
Rated short-time withstand current lcw
1.7kA
Rated operating voltage
690 - 690V
Rated operation power at AC-3, 400 V
30kW
Conditioned rated short-circuit current Iq
2kA
Motor drive optional
No
Motor drive integrated
No
Rated operation power at AC-23, 400 V
55kW
Switching power at 400 V
55kW
Voltage release optional
No
Number of auxiliary contacts as normally closed contact
0
Suitable for floor mounting
No
Suitable for front mounting centre
Yes
Version as emergency stop installation
No
Number of switches
1
Rated permanent current at AC-21, 400 V
100A
Number of auxiliary contacts as change-over contact
0
Number of poles
6
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
No
Suitable for front mounting 4-hole
No
Degree of protection (IP), front side
IP65
With pre-assembled cabling
No
Colour control element
Black
Type of electrical connection of main circuit
Screw connection
Width
88mm
Interlockable
Yes
Type of control element
Door coupling rotary drive
Height
88mm
Degree of protection (NEMA)
12
Suitable for intermediate mounting
No
Depth
156mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
Code: 1042132
T5-3-8342/EA/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
100A
Version as maintenance-/service switch
Version as reversing switch
Rated permanent current Iu
100A
Version as safety switch
Version as main switch
Rated short-time withstand current lcw
1.7kA
Rated operating voltage
690 .. 690V
Rated operation power at AC-3, 400 V
30kW
Conditioned rated short-circuit current Iq
2kA
Motor drive optional
Motor drive integrated
Rated operation power at AC-23, 400 V
55kW
Switching power at 400 V
55kW
Voltage release optional
Number of auxiliary contacts as normally closed contact
0
Suitable for floor mounting
Suitable for front mounting centre
Version as emergency stop installation
Number of switches
1
Rated permanent current at AC-21, 400 V
100A
Number of auxiliary contacts as change-over contact
0
Number of poles
6
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
Suitable for front mounting 4-hole
Degree of protection (IP), front side
IP65
With pre-assembled cabling
Colour control element
Black
Type of electrical connection of main circuit
Screw connection
Width
88mm
Interlockable
Type of control element
Door coupling rotary drive
Height
88mm
Degree of protection (NEMA)
12
Suitable for intermediate mounting
Depth
156mm
From same serie