Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as safety switch
No
Rated short-time withstand current lcw
0.64kA
Version as main switch
Yes
Rated operation power at AC-3, 400 V
13kW
Rated operation power at AC-23, 400 V
15kW
Version as maintenance-/service switch
Yes
Number of auxiliary contacts as change-over contact
0
Conditioned rated short-circuit current Iq
80kA
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
32A
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Rated operating voltage
690 - 690V
Version as reversing switch
No
Number of switches
1
Voltage release optional
No
Rated permanent current Iu
32A
Suitable for floor mounting
No
Device construction
Built-in device fixed built-in technique
Version as emergency stop installation
Yes
Motor drive optional
No
Suitable for front mounting 4-hole
No
Max. rated operation voltage Ue AC
690V
Number of poles
4
Switching power at 400 V
15kW
Rated permanent current at AC-21, 400 V
32A
Interlockable
Yes
Suitable for intermediate mounting
No
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
With pre-assembled cabling
No
Degree of protection (NEMA)
1
Suitable for front mounting centre
No
Width
63mm
Type of electrical connection of main circuit
Screw connection
Colour control element
Red
Suitable for distribution board installation
No
Depth
90mm
Height
70mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
P1-32/V/SVB/N

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as safety switch
Rated short-time withstand current lcw
0.64kA
Version as main switch
Rated operation power at AC-3, 400 V
13kW
Rated operation power at AC-23, 400 V
15kW
Version as maintenance-/service switch
Number of auxiliary contacts as change-over contact
0
Conditioned rated short-circuit current Iq
80kA
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
32A
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Rated operating voltage
690 .. 690V
Version as reversing switch
Number of switches
1
Voltage release optional
Rated permanent current Iu
32A
Suitable for floor mounting
Device construction
Built-in device fixed built-in technique
Version as emergency stop installation
Motor drive optional
Suitable for front mounting 4-hole
Max. rated operation voltage Ue AC
690V
Number of poles
4
Switching power at 400 V
15kW
Rated permanent current at AC-21, 400 V
32A
Interlockable
Suitable for intermediate mounting
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
With pre-assembled cabling
Degree of protection (NEMA)
1
Suitable for front mounting centre
Width
63mm
Type of electrical connection of main circuit
Screw connection
Colour control element
Red
Suitable for distribution board installation
Depth
90mm
Height
70mm
From same serie
Related products