Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
63A
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as main switch
Yes
Version as reversing switch
No
Version as emergency stop installation
Yes
Rated operating voltage
690 - 690V
Number of switches
1
Rated permanent current at AC-21, 400 V
63A
Rated permanent current Iu
63A
Rated operation power at AC-3, 400 V
22kW
Rated short-time withstand current lcw
1.3kA
Switching power at 400 V
30kW
Rated operation power at AC-23, 400 V
30kW
Conditioned rated short-circuit current Iq
2kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
No
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
With pre-assembled cabling
No
Height
88mm
Motor drive integrated
No
Suitable for front mounting centre
No
Suitable for distribution board installation
No
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
Yes
Depth
155mm
Degree of protection (IP), front side
IP65
Colour control element
Red
Width
88mm
Degree of protection (NEMA)
12
Type of control element
Door coupling rotary drive
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
T5B-2-1/V/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
63A
Version as maintenance-/service switch
Version as safety switch
Version as main switch
Version as reversing switch
Version as emergency stop installation
Rated operating voltage
690 .. 690V
Number of switches
1
Rated permanent current at AC-21, 400 V
63A
Rated permanent current Iu
63A
Rated operation power at AC-3, 400 V
22kW
Rated short-time withstand current lcw
1.3kA
Switching power at 400 V
30kW
Rated operation power at AC-23, 400 V
30kW
Conditioned rated short-circuit current Iq
2kA
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Type of electrical connection of main circuit
Screw connection
Interlockable
With pre-assembled cabling
Height
88mm
Motor drive integrated
Suitable for front mounting centre
Suitable for distribution board installation
Motor drive optional
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Depth
155mm
Degree of protection (IP), front side
IP65
Colour control element
Red
Width
88mm
Degree of protection (NEMA)
12
Type of control element
Door coupling rotary drive
From same serie