Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
63A
Version as main switch
Yes
Version as emergency stop installation
Yes
Version as maintenance-/service switch
Yes
Rated permanent current at AC-21, 400 V
63A
Version as reversing switch
No
Rated operation power at AC-3, 400 V
22kW
Number of switches
1
Rated short-time withstand current lcw
1.3kA
Rated operation power at AC-23, 400 V
30kW
Number of poles
6
Version as safety switch
No
Switching power at 400 V
30kW
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting 4-hole
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Rated permanent current Iu
63A
Suitable for front mounting centre
Yes
Suitable for floor mounting
No
Conditioned rated short-circuit current Iq
2kA
Motor drive integrated
No
Rated operating voltage
690 - 690V
Motor drive optional
No
With pre-assembled cabling
No
Suitable for distribution board installation
No
Colour control element
Red
Suitable for intermediate mounting
No
Interlockable
Yes
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Width
88mm
Type of electrical connection of main circuit
Screw connection
Depth
173mm
Height
88mm
Type of control element
Door coupling rotary drive
From same serie
T5B-4-15164/EA/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
63A
Version as main switch
Version as emergency stop installation
Version as maintenance-/service switch
Rated permanent current at AC-21, 400 V
63A
Version as reversing switch
Rated operation power at AC-3, 400 V
22kW
Number of switches
1
Rated short-time withstand current lcw
1.3kA
Rated operation power at AC-23, 400 V
30kW
Number of poles
6
Version as safety switch
Switching power at 400 V
30kW
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting 4-hole
Voltage release optional
Device construction
Built-in device fixed built-in technique
Rated permanent current Iu
63A
Suitable for front mounting centre
Suitable for floor mounting
Conditioned rated short-circuit current Iq
2kA
Motor drive integrated
Rated operating voltage
690 .. 690V
Motor drive optional
With pre-assembled cabling
Suitable for distribution board installation
Colour control element
Red
Suitable for intermediate mounting
Interlockable
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Width
88mm
Type of electrical connection of main circuit
Screw connection
Depth
173mm
Height
88mm
Type of control element
Door coupling rotary drive
From same serie
We use cookies to enhance your experience.