Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
63A
Version as safety switch
No
Version as emergency stop installation
No
Version as reversing switch
No
Number of switches
1
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Rated operating voltage
690 - 690V
Rated permanent current at AC-21, 400 V
63A
Rated permanent current Iu
63A
Rated short-time withstand current lcw
1.3kA
Rated operation power at AC-3, 400 V
22kW
Number of poles
6
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-23, 400 V
30kW
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Suitable for floor mounting
No
Motor drive optional
No
Motor drive integrated
No
Suitable for front mounting 4-hole
No
Voltage release optional
No
Suitable for distribution board installation
No
Suitable for intermediate mounting
No
Colour control element
Black
Device construction
Built-in device fixed built-in technique
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Conditioned rated short-circuit current Iq
2kA
Switching power at 400 V
30kW
With pre-assembled cabling
No
Degree of protection (NEMA)
12
Height
88mm
Width
88mm
Depth
173mm
Interlockable
Yes
Suitable for front mounting centre
Yes
From same serie
T5B-4-15164/EA/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
63A
Version as safety switch
Version as emergency stop installation
Version as reversing switch
Number of switches
1
Version as main switch
Version as maintenance-/service switch
Rated operating voltage
690 .. 690V
Rated permanent current at AC-21, 400 V
63A
Rated permanent current Iu
63A
Rated short-time withstand current lcw
1.3kA
Rated operation power at AC-3, 400 V
22kW
Number of poles
6
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-23, 400 V
30kW
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Suitable for floor mounting
Motor drive optional
Motor drive integrated
Suitable for front mounting 4-hole
Voltage release optional
Suitable for distribution board installation
Suitable for intermediate mounting
Colour control element
Black
Device construction
Built-in device fixed built-in technique
Type of control element
Door coupling rotary drive
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Conditioned rated short-circuit current Iq
2kA
Switching power at 400 V
30kW
With pre-assembled cabling
Degree of protection (NEMA)
12
Height
88mm
Width
88mm
Depth
173mm