Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current at AC-23, 400 V
13.3A
Version as main switch
Yes
Version as safety switch
No
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Number of switches
1
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 - 690V
Rated permanent current Iu
20A
Rated short-time withstand current lcw
0.32kA
Rated operation power at AC-23, 400 V
5.5kW
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Number of poles
3
Switching power at 400 V
5.5kW
Conditioned rated short-circuit current Iq
6kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Motor drive optional
No
Number of auxiliary contacts as change-over contact
0
Suitable for intermediate mounting
No
Suitable for floor mounting
No
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
Yes
Suitable for distribution board installation
No
Colour control element
Black
Interlockable
Yes
With pre-assembled cabling
No
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Width
65mm
Height
74mm
Depth
111mm
Type of control element
Door coupling rotary drive
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
T0-2-1/EA/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current at AC-23, 400 V
13.3A
Version as main switch
Version as safety switch
Version as maintenance-/service switch
Version as reversing switch
Number of switches
1
Version as emergency stop installation
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 .. 690V
Rated permanent current Iu
20A
Rated short-time withstand current lcw
0.32kA
Rated operation power at AC-23, 400 V
5.5kW
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Number of poles
3
Switching power at 400 V
5.5kW
Conditioned rated short-circuit current Iq
6kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Voltage release optional
Device construction
Built-in device fixed built-in technique
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Suitable for intermediate mounting
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for front mounting centre
Suitable for distribution board installation
Colour control element
Black
Interlockable
With pre-assembled cabling
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Width
65mm
Height
74mm
Depth
111mm
Type of control element
Door coupling rotary drive
From same serie