Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
32A
Version as reversing switch
No
Rated operating voltage
690 - 690V
Number of switches
1
Version as main switch
Yes
Rated permanent current at AC-21, 400 V
32A
Version as safety switch
No
Version as maintenance-/service switch
Yes
Rated operation power at AC-23, 400 V
15kW
Rated short-time withstand current lcw
0.65kA
Rated permanent current Iu
32A
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 400 V
11kW
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as change-over contact
0
Number of poles
3
Motor drive integrated
No
Switching power at 400 V
15kW
Suitable for front mounting 4-hole
No
Conditioned rated short-circuit current Iq
1kA
Voltage release optional
No
Suitable for intermediate mounting
No
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Suitable for distribution board installation
No
Suitable for front mounting centre
Yes
Version as emergency stop installation
Yes
Motor drive optional
No
Interlockable
Yes
Colour control element
Red
Type of control element
Door coupling rotary drive
Type of electrical connection of main circuit
Screw connection
Degree of protection (NEMA)
12
Height
74mm
With pre-assembled cabling
No
Degree of protection (IP), front side
IP65
Depth
127mm
Width
65mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
T3-3-15683/EA/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
32A
Version as reversing switch
Rated operating voltage
690 .. 690V
Number of switches
1
Version as main switch
Rated permanent current at AC-21, 400 V
32A
Version as safety switch
Version as maintenance-/service switch
Rated operation power at AC-23, 400 V
15kW
Rated short-time withstand current lcw
0.65kA
Rated permanent current Iu
32A
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 400 V
11kW
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as change-over contact
0
Number of poles
3
Motor drive integrated
Switching power at 400 V
15kW
Suitable for front mounting 4-hole
Conditioned rated short-circuit current Iq
1kA
Voltage release optional
Suitable for intermediate mounting
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Suitable for distribution board installation
Suitable for front mounting centre
Version as emergency stop installation
Motor drive optional
Interlockable
Colour control element
Red
Type of control element
Door coupling rotary drive
Type of electrical connection of main circuit
Screw connection
Degree of protection (NEMA)
12
Height
74mm
With pre-assembled cabling
Degree of protection (IP), front side
IP65
Depth
127mm
Width
65mm
From same serie
Related products
We use cookies to enhance your experience.