Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
No
Version as maintenance-/service switch
No
Version as safety switch
No
Version as reversing switch
No
Rated permanent current Iu
63A
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 - 690V
Rated permanent current at AC-23, 400 V
63A
Rated operation power at AC-23, 400 V
30kW
Version as emergency stop installation
No
Rated short-time withstand current lcw
1.26kA
Rated permanent current at AC-21, 400 V
63A
Switching power at 400 V
30kW
Number of auxiliary contacts as normally open contact
0
Conditioned rated short-circuit current Iq
100kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
30kW
Number of switches
1
Suitable for floor mounting
Yes
Number of poles
4
Voltage release optional
No
Suitable for front mounting 4-hole
No
Motor drive integrated
No
Suitable for distribution board installation
No
Motor drive optional
No
Type of control element
Door coupling rotary drive
Suitable for front mounting centre
No
Suitable for intermediate mounting
Yes
Colour control element
Black
Type of electrical connection of main circuit
Screw connection
Interlockable
No
With pre-assembled cabling
No
Device construction
Built-in device fixed built-in technique
Width
90mm
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Height
87mm
Depth
140mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
P3-63/Z/N

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as maintenance-/service switch
Version as safety switch
Version as reversing switch
Rated permanent current Iu
63A
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 .. 690V
Rated permanent current at AC-23, 400 V
63A
Rated operation power at AC-23, 400 V
30kW
Version as emergency stop installation
Rated short-time withstand current lcw
1.26kA
Rated permanent current at AC-21, 400 V
63A
Switching power at 400 V
30kW
Number of auxiliary contacts as normally open contact
0
Conditioned rated short-circuit current Iq
100kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
30kW
Number of switches
1
Suitable for floor mounting
Number of poles
4
Voltage release optional
Suitable for front mounting 4-hole
Motor drive integrated
Suitable for distribution board installation
Motor drive optional
Type of control element
Door coupling rotary drive
Suitable for front mounting centre
Suitable for intermediate mounting
Colour control element
Black
Type of electrical connection of main circuit
Screw connection
Interlockable
With pre-assembled cabling
Device construction
Built-in device fixed built-in technique
Width
90mm
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Height
87mm
Depth
140mm
From same serie
Related products
We use cookies to enhance your experience.