P1-25/V/SVB/2HI11
Code: 1034964
Code: 1034964
Number of poles
3
Type of control element
Door coupling rotary drive
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as normally closed contact
2
Rated permanent current Iu
25A
Motor drive optional
No
Motor drive integrated
No
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
7.5kW
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Suitable for floor mounting
No
Suitable for intermediate mounting
Yes
Suitable for distribution board installation
No
Conditioned rated short-circuit current Iq
80kA
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 - 690V
Suitable for front mounting 4-hole
No
Version as emergency stop installation
Yes
Version as safety switch
No
Voltage release optional
No
Interlockable
Yes
Version as maintenance-/service switch
Yes
Switching power at 400 V
13kW
Number of switches
1
Rated permanent current at AC-23, 400 V
25A
Rated short-time withstand current lcw
0.64kA
Rated operation power at AC-23, 400 V
13kW
Colour control element
Red
Version as reversing switch
No
Suitable for front mounting centre
No
Rated permanent current at AC-21, 400 V
25A
Version as main switch
Yes
Zagreb:
0 pcs
Zadar:
0 pcs
P1-25/V/SVB/2HI11
Number of poles
3
Type of control element
Door coupling rotary drive
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as normally closed contact
2
Rated permanent current Iu
25A
Motor drive optional
Motor drive integrated
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-3, 400 V
7.5kW
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Suitable for floor mounting
Suitable for intermediate mounting
Suitable for distribution board installation
Conditioned rated short-circuit current Iq
80kA
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 .. 690V
Suitable for front mounting 4-hole
Version as emergency stop installation
Version as safety switch
Voltage release optional
Interlockable
Version as maintenance-/service switch
Switching power at 400 V
13kW
Number of switches
1
Rated permanent current at AC-23, 400 V
25A
Rated short-time withstand current lcw
0.64kA
Rated operation power at AC-23, 400 V
13kW
Colour control element
Red
Version as reversing switch
Suitable for front mounting centre
Rated permanent current at AC-21, 400 V
25A
Version as main switch