Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
32A
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Version as emergency stop installation
Yes
Number of switches
1
Rated operating voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated short-time withstand current lcw
0.65kA
Rated operation power at AC-3, 400 V
11kW
Rated operation power at AC-23, 400 V
15kW
Version as safety switch
No
Conditioned rated short-circuit current Iq
1kA
Number of poles
9
Suitable for front mounting 4-hole
No
Number of auxiliary contacts as change-over contact
0
Suitable for distribution board installation
No
Rated permanent current at AC-21, 400 V
32A
Motor drive integrated
No
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Voltage release optional
No
Suitable for floor mounting
Yes
Suitable for intermediate mounting
Yes
With pre-assembled cabling
No
Switching power at 400 V
15kW
Suitable for front mounting centre
No
Degree of protection (IP), front side
IP65
Depth
167mm
Colour control element
Red
Interlockable
Yes
Height
74mm
Type of control element
Door coupling rotary drive
Degree of protection (NEMA)
12
Width
65mm
Type of electrical connection of main circuit
Screw connection
Rated permanent current Iu
32A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
T3-5-8345/V/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
32A
Version as main switch
Version as maintenance-/service switch
Version as reversing switch
Version as emergency stop installation
Number of switches
1
Rated operating voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated short-time withstand current lcw
0.65kA
Rated operation power at AC-3, 400 V
11kW
Rated operation power at AC-23, 400 V
15kW
Version as safety switch
Conditioned rated short-circuit current Iq
1kA
Number of poles
9
Suitable for front mounting 4-hole
Number of auxiliary contacts as change-over contact
0
Suitable for distribution board installation
Rated permanent current at AC-21, 400 V
32A
Motor drive integrated
Motor drive optional
Device construction
Built-in device fixed built-in technique
Voltage release optional
Suitable for floor mounting
Suitable for intermediate mounting
With pre-assembled cabling
Switching power at 400 V
15kW
Suitable for front mounting centre
Degree of protection (IP), front side
IP65
Depth
167mm
Colour control element
Red
Interlockable
Height
74mm
Type of control element
Door coupling rotary drive
Degree of protection (NEMA)
12
Width
65mm
Type of electrical connection of main circuit
Screw connection
Rated permanent current Iu
32A
From same serie