Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
800A
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as emergency stop installation
Yes
Number of switches
1
Version as reversing switch
No
Rated operation power at AC-3, 400 V
0kW
Rated operation power at AC-23, 400 V
450kW
Rated permanent current at AC-21, 400 V
0A
Rated permanent current at AC-23, 400 V
0A
Version as main switch
Yes
Max. rated operation voltage Ue AC
690V
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
0kA
Number of poles
4
Number of auxiliary contacts as change-over contact
0
Switching power at 400 V
0kW
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Rated operating voltage
690 - 690V
Rated short-time withstand current lcw
25kA
Voltage release optional
Yes
Suitable for front mounting 4-hole
No
Motor drive integrated
No
Suitable for floor mounting
Yes
Suitable for intermediate mounting
Yes
Device construction
Built-in device fixed built-in technique
Colour control element
Black
Suitable for distribution board installation
Yes
Suitable for front mounting centre
No
Interlockable
Yes
Type of electrical connection of main circuit
Bolt connection
With pre-assembled cabling
No
Type of control element
Rocker lever
Degree of protection (IP), front side
IP20
Height
207mm
Depth
401mm
Width
280mm
Related products
From same serie
N4-4-800

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
800A
Version as maintenance-/service switch
Version as safety switch
Version as emergency stop installation
Number of switches
1
Version as reversing switch
Rated operation power at AC-3, 400 V
0kW
Rated operation power at AC-23, 400 V
450kW
Rated permanent current at AC-21, 400 V
0A
Rated permanent current at AC-23, 400 V
0A
Version as main switch
Max. rated operation voltage Ue AC
690V
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
0kA
Number of poles
4
Number of auxiliary contacts as change-over contact
0
Switching power at 400 V
0kW
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Rated operating voltage
690 .. 690V
Rated short-time withstand current lcw
25kA
Voltage release optional
Suitable for front mounting 4-hole
Motor drive integrated
Suitable for floor mounting
Suitable for intermediate mounting
Device construction
Built-in device fixed built-in technique
Colour control element
Black
Suitable for distribution board installation
Suitable for front mounting centre
Interlockable
Type of electrical connection of main circuit
Bolt connection
With pre-assembled cabling
Type of control element
Rocker lever
Degree of protection (IP), front side
IP20
Height
207mm
Depth
401mm
Width
280mm
From same serie