Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
1600 - 16000A
Adjustment range undelayed short-circuit release
3200 - 19200A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
With integrated under voltage release
No
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Overload release current setting
800 - 1600A
Number of auxiliary contacts as change-over contact
0
Number of poles
4
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Position of connection for main current circuit
Front side
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of control element
Rocker lever
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMH4-4-VE1600

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Rated permanent current Iu
1600A
Adjustment range short-term delayed short-circuit release
1600 .. 16000A
Adjustment range undelayed short-circuit release
3200 .. 19200A
Integrated earth fault protection
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
With integrated under voltage release
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Overload release current setting
800 .. 1600A
Number of auxiliary contacts as change-over contact
0
Number of poles
4
DIN rail (top hat rail) mounting optional
Motor drive optional
Position of connection for main current circuit
Front side
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of control element
Rocker lever
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
From same serie
Related products
We use cookies to enhance your experience.