Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range undelayed short-circuit release
1600 - 9600A
Number of auxiliary contacts as normally closed contact
0
Adjustment range short-term delayed short-circuit release
0 - 0A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
Position of connection for main current circuit
Front side
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
No
Number of poles
4
With integrated under voltage release
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Motor drive optional
Yes
Degree of protection (IP)
IP20
Rated voltage
690 - 690V
Rated permanent current Iu
800A
Motor drive integrated
No
Overload release current setting
400 - 800A
Type of control element
Rocker lever
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
NZMH4-4-AE800/500

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Adjustment range undelayed short-circuit release
1600 .. 9600A
Number of auxiliary contacts as normally closed contact
0
Adjustment range short-term delayed short-circuit release
0 .. 0A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Position of connection for main current circuit
Front side
Type of electrical connection of main circuit
Screw connection
With switched-off indicator
Number of poles
4
With integrated under voltage release
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Motor drive optional
Degree of protection (IP)
IP20
Rated voltage
690 .. 690V
Rated permanent current Iu
800A
Motor drive integrated
Overload release current setting
400 .. 800A
Type of control element
Rocker lever
Complete device with protection unit