Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

No

Built-in depth

70.5mm

Rated current

2A

Rated voltage

230V

Width in number of modular spacings

1

Release characteristic

B

Ambient temperature during operating

-25 - 75°C

Connectable conductor cross section multi-wired

1 - 25mm²

Number of protected poles

1

Connectable conductor cross section solid-core

1 - 25mm²

Over voltage category

3

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Additional equipment possible

Yes

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA


Warehouse states

Zagreb:

17 pcs

Zadar:

2 pcs


Related products


Recommended products


From same serie


Substitute products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

PL6-B2/1

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Built-in depth

70.5mm

Rated current

2A

Rated voltage

230V

Width in number of modular spacings

1

Release characteristic

B

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

1

Connectable conductor cross section solid-core

1 .. 25mm²

Over voltage category

3

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Additional equipment possible

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

From same serie

Related products

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.