  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Built-in depth

75mm

Suitable for flush-mounted installation

No

Rated current

80A

Rated voltage

400V

Width in number of modular spacings

4.5

Release characteristic

C

Ambient temperature during operating

-25 - 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Connectable conductor cross section multi-wired

2.5 - 50mm²

Number of protected poles

3

Connectable conductor cross section solid-core

2.5 - 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Additional equipment possible

Yes

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

PLHT-C80/3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Built-in depth

75mm

Suitable for flush-mounted installation

Rated current

80A

Rated voltage

400V

Width in number of modular spacings

4.5

Release characteristic

C

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Number of protected poles

3

Connectable conductor cross section solid-core

2.5 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Over voltage category

3

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Additional equipment possible

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA