- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Nominal output current I2N
477A
Mains voltage
380 - 440V
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
250kW
Max. output frequency
500Hz
Max. output voltage
440V
Relative symmetric net frequency tolerance
5%
Max. output at linear load at rated output voltage
250kW
Number of phases input
3
Number of analogue inputs
3
Number of analogue outputs
2
Supporting protocol for PROFIBUS
Yes
Application in industrial area permitted
Yes
Supporting protocol for TCP/IP
Yes
Relative symmetric net voltage tolerance
10%
With control element
Yes
Application in domestic- and commercial area permitted
Yes
Number of digital outputs
0
Supporting protocol for KNX
No
Number of digital inputs
6
Supporting protocol for CAN
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Modbus
Yes
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFINET IO
Yes
With optical interface
No
With PC connection
No
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP21
Width
600mm
Height
2150mm
Depth
605mm
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
No
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV630C25N4F
![Main Product Image](https://assets.aleta.hr/300x300/606fedab-31e6-4319-bb29-c66277a12c91_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Nominal output current I2N
477A
Mains voltage
380 .. 440V
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
250kW
Max. output frequency
500Hz
Max. output voltage
440V
Relative symmetric net frequency tolerance
5%
Max. output at linear load at rated output voltage
250kW
Number of phases input
3
Number of analogue inputs
3
Number of analogue outputs
2
Supporting protocol for PROFIBUS
Application in industrial area permitted
Supporting protocol for TCP/IP
Relative symmetric net voltage tolerance
10%
With control element
Application in domestic- and commercial area permitted
Number of digital outputs
0
Supporting protocol for KNX
Number of digital inputs
6
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP21
Width
600mm
Height
2150mm
Depth
605mm
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
From same serie
We use cookies to enhance your experience.