- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Max. output voltage
480V
Max. output frequency
200Hz
Max. output at linear load at rated output voltage
5.5kW
Mains voltage
380 - 480V
Max. output at quadratic load at rated output voltage
5.5kW
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Number of digital outputs
0
Application in domestic- and commercial area permitted
Yes
Number of phases input
3
Number of digital inputs
3
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Nominal output current I2N
12A
With control element
Yes
Application in industrial area permitted
Yes
Supporting protocol for TCP/IP
No
Number of analogue inputs
2
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Relative symmetric net frequency tolerance
5%
Supporting protocol for ASI
No
Number of analogue outputs
1
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Degree of protection (IP)
IP55
Height
340mm
Depth
208mm
Width
230mm
Supporting protocol for PROFIsafe
No
Type of converter
U converter
Supporting protocol for SUCONET
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for LON
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for BACnet
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces parallel
0
Supporting protocol for SERCOS
No
Number of HW-interfaces serial TTY
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
Yes
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces RS-422
0
Supporting protocol for Modbus
Yes
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212WU55N4
![Main Product Image](https://assets.aleta.hr/300x300/30c8912d-8ad8-4424-bb98-68d06b78073b_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Max. output voltage
480V
Max. output frequency
200Hz
Max. output at linear load at rated output voltage
5.5kW
Mains voltage
380 .. 480V
Max. output at quadratic load at rated output voltage
5.5kW
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Number of digital outputs
0
Application in domestic- and commercial area permitted
Number of phases input
3
Number of digital inputs
3
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Nominal output current I2N
12A
With control element
Application in industrial area permitted
Supporting protocol for TCP/IP
Number of analogue inputs
2
Supporting protocol for INTERBUS
Supporting protocol for KNX
Relative symmetric net frequency tolerance
5%
Supporting protocol for ASI
Number of analogue outputs
1
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Degree of protection (IP)
IP55
Height
340mm
Depth
208mm
Width
230mm
Supporting protocol for PROFIsafe
Type of converter
U converter
Supporting protocol for SUCONET
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for EtherNet/IP
Supporting protocol for BACnet
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces parallel
0
Supporting protocol for SERCOS
Number of HW-interfaces serial TTY
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for DeviceNet Safety
Number of HW-interfaces RS-422
0
Supporting protocol for Modbus
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces other