Aleta.hr
Main Product Image

33563

Code: 1691206

ManufacturerRAZNO
Catalog number33563
Type
EAN code3303430335634

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated permanent current Iu

1000A

Rated voltage

690 - 690V

Adjustment range short-term delayed short-circuit release

600 - 10000A

Overload release current setting

400 - 1000A

Adjustment range undelayed short-circuit release

2000 - 15000A

Device construction

Built-in device fixed built-in technique

Power loss

136W

Integrated earth fault protection

No

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

No

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

No

With switched-off indicator

Yes

With integrated under voltage release

No

Number of poles

4

Type of control element

Toggle

Complete device with protection unit

Yes

Motor drive integrated

No

Motor drive optional

Yes

Degree of protection (IP)

IP40

Position of connection for main current circuit

Front side


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

33563

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated permanent current Iu

1000A

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

600 .. 10000A

Overload release current setting

400 .. 1000A

Adjustment range undelayed short-circuit release

2000 .. 15000A

Device construction

Built-in device fixed built-in technique

Power loss

136W

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

With integrated under voltage release

Number of poles

4

Type of control element

Toggle

Complete device with protection unit

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP40

Position of connection for main current circuit

Front side

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.