![Main Product Image](https://assets.aleta.hr/415x415/42980e12-e574-4815-8204-93b96c065e98.webp)
![Main Product Image](https://assets.aleta.hr/415x415/42980e12-e574-4815-8204-93b96c065e98.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
800A
Overload release current setting
320 - 800A
Integrated earth fault protection
No
Power loss
45W
Adjustment range undelayed short-circuit release
1200 - 8000A
Device construction
Built-in device fixed built-in technique
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
With integrated under voltage release
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
0
Complete device with protection unit
Yes
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP40
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Toggle
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33467
![Main Product Image](https://assets.aleta.hr/300x300/dd2bfc3b-1d64-41ea-a55c-9768cc42b836_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
800A
Overload release current setting
320 .. 800A
Integrated earth fault protection
Power loss
45W
Adjustment range undelayed short-circuit release
1200 .. 8000A
Device construction
Built-in device fixed built-in technique
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
With integrated under voltage release
With switched-off indicator
Number of auxiliary contacts as change-over contact
0
Complete device with protection unit
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP40
Number of poles
3
Position of connection for main current circuit
Front side
Type of control element
Toggle
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0