- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
252 - 630A
Adjustment range undelayed short-circuit release
945 - 6300A
Rated permanent current Iu
630A
Device construction
Built-in device fixed built-in technique
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Front side
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Motor drive integrated
No
Number of poles
4
With switched-off indicator
Yes
Complete device with protection unit
Yes
Motor drive optional
Yes
Integrated earth fault protection
No
Degree of protection (IP)
IP40
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33464
![Main Product Image](https://assets.aleta.hr/300x300/c264964a-3d26-4c85-b6a9-eb5033518a73_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
252 .. 630A
Adjustment range undelayed short-circuit release
945 .. 6300A
Rated permanent current Iu
630A
Device construction
Built-in device fixed built-in technique
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Front side
With integrated under voltage release
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Motor drive integrated
Number of poles
4
With switched-off indicator
Complete device with protection unit
Motor drive optional
Integrated earth fault protection
Degree of protection (IP)
IP40