![Main Product Image](https://assets.aleta.hr/415x415/bb884af8-6fb6-47b9-841b-27ee4e4d5f2b.webp)
![Main Product Image](https://assets.aleta.hr/415x415/bb884af8-6fb6-47b9-841b-27ee4e4d5f2b.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
1250A
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Bolt connection
Complete device with protection unit
No
With integrated under voltage release
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
0
Motor drive optional
No
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP40
Motor drive integrated
Yes
Type of control element
Push button
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 - 690V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33401
![Main Product Image](https://assets.aleta.hr/300x300/630bdfa8-d85b-4770-b27c-8d9117501f92_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
1250A
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Bolt connection
Complete device with protection unit
With integrated under voltage release
With switched-off indicator
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP40
Motor drive integrated
Type of control element
Push button
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 .. 690V
From same serie