![Main Product Image](https://assets.aleta.hr/415x415/6605bbcf-9eee-4dd1-9ddd-d13451dec2ad.webp)
![Main Product Image](https://assets.aleta.hr/415x415/6605bbcf-9eee-4dd1-9ddd-d13451dec2ad.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Rated voltage
690 - 690V
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
No
With switched-off indicator
Yes
Type of control element
Push button
Complete device with protection unit
No
Number of poles
4
Motor drive optional
No
Degree of protection (IP)
IP40
Position of connection for main current circuit
Front side
Motor drive integrated
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33396
![Main Product Image](https://assets.aleta.hr/300x300/36091e2a-aef2-4dbd-b019-ce5d4c992a7f_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Rated voltage
690 .. 690V
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
With switched-off indicator
Type of control element
Push button
Complete device with protection unit
Number of poles
4
Motor drive optional
Degree of protection (IP)
IP40
Position of connection for main current circuit
Front side
Motor drive integrated
From same serie
We use cookies to enhance your experience.