![Main Product Image](https://assets.aleta.hr/415x415/462618d3-6e9c-442d-97c1-8c7eaf17d7e2.webp)
![Main Product Image](https://assets.aleta.hr/415x415/462618d3-6e9c-442d-97c1-8c7eaf17d7e2.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
800A
Rated voltage
690 - 690V
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Complete device with protection unit
No
Degree of protection (IP)
IP40
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
No
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
With integrated under voltage release
No
Position of connection for main current circuit
Front side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33335
![Main Product Image](https://assets.aleta.hr/300x300/eedc79b1-28a5-4df3-9982-c434d7d36faf_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
800A
Rated voltage
690 .. 690V
With switched-off indicator
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Complete device with protection unit
Degree of protection (IP)
IP40
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Motor drive optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
With integrated under voltage release
Position of connection for main current circuit
Front side
From same serie