![Main Product Image](https://assets.aleta.hr/415x415/ac6301a5-c649-4556-90e3-6fc292d59c47.webp)
![Main Product Image](https://assets.aleta.hr/415x415/ac6301a5-c649-4556-90e3-6fc292d59c47.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
With integrated under voltage release
No
Motor drive integrated
Yes
Degree of protection (IP)
IP40
Number of poles
4
Rated permanent current Iu
800A
Device construction
Built-in device fixed built-in technique
Position of connection for main current circuit
Front side
Complete device with protection unit
No
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
No
Number of auxiliary contacts as change-over contact
0
Rated voltage
690 - 690V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33286
![Main Product Image](https://assets.aleta.hr/300x300/aa289ed4-26b3-44ba-a10f-749b598b5ff5_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
With integrated under voltage release
Motor drive integrated
Degree of protection (IP)
IP40
Number of poles
4
Rated permanent current Iu
800A
Device construction
Built-in device fixed built-in technique
Position of connection for main current circuit
Front side
Complete device with protection unit
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Rated voltage
690 .. 690V