- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
945.0 - 9450A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
630A
Integrated earth fault protection
Yes
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
252.0 - 630A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Complete device with protection unit
Yes
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1614889
1SDA072063R1 | E1.2C 630 EKIP DIP LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
630A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
252.0 .. 630A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Complete device with protection unit
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional