Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
630A
Rated voltage
690 - 690V
Overload release current setting
252.0 - 630A
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
945.0 - 9450A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Number of poles
3
With switched-off indicator
Yes
Complete device with protection unit
Yes
Suitable for DIN rail (top hat rail) mounting
No
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072061R1 | E1.2C 630 EKIP DIP LI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
630A
Rated voltage
690 .. 690V
Overload release current setting
252.0 .. 630A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Number of poles
3
With switched-off indicator
Complete device with protection unit
Suitable for DIN rail (top hat rail) mounting
Degree of protection (IP)
IP30