Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
630A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
Yes
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Number of poles
3
Type of control element
Push button
Motor drive integrated
No
Adjustment range undelayed short-circuit release
945.0 - 9450A
Overload release current setting
252.0 - 630A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA072053R1 | E1.2B 630 EKIP DIP LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
630A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Number of poles
3
Type of control element
Push button
Motor drive integrated
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Overload release current setting
252.0 .. 630A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
From same serie