- Circuit breakers and fuses
- Earth leakage circuit breaker
- 1 KOM
- ABB
Technical specifications
Connectable conductor cross section multi-wired
mm²
Connectable conductor cross section solid-core
mm²
Rated impulse withstand voltage Uimp
-kV
Current limiting class
-
Rated insulation voltage Ui
-V
Rated short-circuit breaking capacity Icn according to EN 61009-1
-kA
Surge current capacity
0kA
Number of poles (total)
2
Rated short-circuit breaking capacity according to EN 61009
10kA
Leakage current type
AC
Rated current
10A
Rated voltage
230V
Voltage type
AC
With interlocking device
No
Rated fault current
0.3A
Rated short-circuit breaking capacity according to IEC 60947-2
15kA
Frequency
50/60 Hz
Concurrently switching neutral conductor
Yes
Number of protected poles
1
Ambient temperature during operating
-25 - 55°C
Over voltage category
3
Width in number of modular spacings
2
Pollution degree
2
Release characteristic
C
Suitable for flush-mounted installation
No
Anti-nuisance tripping version
No
Degree of protection (IP)
IP2X
Built-in depth
69mm
Warehouse states
Zagreb:
25 pcs
Zadar:
0 pcs
From same serie
2CSR275080R3104 | DS201 M C10 AC300
![Main Product Image](https://assets.aleta.hr/300x300/967101a7-5952-4f07-9e5e-6018f349dc12_optimized.webp)
Details
- Circuit breakers and fuses
- Earth leakage circuit breaker
- 1 KOM
- ABB
Technical specifications
Connectable conductor cross section multi-wired
mm²
Connectable conductor cross section solid-core
mm²
Rated impulse withstand voltage Uimp
-kV
Current limiting class
-
Rated insulation voltage Ui
-V
Rated short-circuit breaking capacity Icn according to EN 61009-1
-kA
Surge current capacity
0kA
Number of poles (total)
2
Rated short-circuit breaking capacity according to EN 61009
10kA
Leakage current type
AC
Rated current
10A
Rated voltage
230V
Voltage type
AC
With interlocking device
Rated fault current
0.3A
Rated short-circuit breaking capacity according to IEC 60947-2
15kA
Frequency
50/60 Hz
Concurrently switching neutral conductor
Number of protected poles
1
Ambient temperature during operating
-25 .. 55°C
Over voltage category
3
Width in number of modular spacings
2
Pollution degree
2
Release characteristic
C
Suitable for flush-mounted installation
Anti-nuisance tripping version
Degree of protection (IP)
IP2X
Built-in depth
69mm