![Main Product Image](https://assets.aleta.hr/415x415/33d159a6-7cc2-4413-879c-3e77842f44e3.webp)
![Main Product Image](https://assets.aleta.hr/415x415/33d159a6-7cc2-4413-879c-3e77842f44e3.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Number of protected poles
3
Rated impulse withstand voltage Uimp
4kV
Rated current
16A
Rated voltage
400V
Number of poles (total)
3
Rated insulation voltage Ui
440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6kA
Voltage type
AC
Release characteristic
D
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10kA
Current limiting class
3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
20kA
Suitable for flush-mounted installation
No
Pollution degree
3
Concurrently switching neutral conductor
No
Additional equipment possible
Yes
Width in number of modular spacings
3
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 - 55°C
Connectable conductor cross section multi-wired
0 - 25mm²
Connectable conductor cross section solid-core
0 - 35mm²
Frequency
50 - 60Hz
Over voltage category
3
Built-in depth
69mm
Warehouse states
Zagreb:
6 pcs
Zadar:
0 pcs
From same serie
2CDS253001R0161 | S203-D16
![Main Product Image](https://assets.aleta.hr/300x300/1a0192b3-8856-4e6e-85fa-c8f8c55106c5_optimized.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Number of protected poles
3
Rated impulse withstand voltage Uimp
4kV
Rated current
16A
Rated voltage
400V
Number of poles (total)
3
Rated insulation voltage Ui
440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6kA
Voltage type
AC
Release characteristic
D
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10kA
Current limiting class
3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
20kA
Suitable for flush-mounted installation
Pollution degree
3
Concurrently switching neutral conductor
Additional equipment possible
Width in number of modular spacings
3
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 .. 55°C
Connectable conductor cross section multi-wired
0 .. 25mm²
Connectable conductor cross section solid-core
0 .. 35mm²
Frequency
50 .. 60Hz
Over voltage category
3
Built-in depth
69mm