Aleta.hr
Main Product Image

2CDS253001R0101 | S203-D10

Code: 1549316

ManufacturerRAZNO
Catalog number2CDS253001R0101
Type
EAN code4016779530903
Additional quantity for delivery +30 kom
14.02.2025 + 30 pcs

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Number of protected poles

3

Rated current

10A

Rated impulse withstand voltage Uimp

4kV

Release characteristic

D

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Current limiting class

3

Concurrently switching neutral conductor

No

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Frequency

50 - 60Hz

Rated voltage

400V

Over voltage category

3

Suitable for flush-mounted installation

No

Degree of protection (IP)

IP20

Number of poles (total)

3

Width in number of modular spacings

3

Additional equipment possible

Yes

Pollution degree

3

Built-in depth

69mm

Connectable conductor cross section solid-core

0 - 35mm²

Connectable conductor cross section multi-wired

0 - 25mm²

Ambient temperature during operating

-25 - 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA


Warehouse states

Zagreb:

3 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS253001R0101 | S203-D10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Number of protected poles

3

Rated current

10A

Rated impulse withstand voltage Uimp

4kV

Release characteristic

D

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Current limiting class

3

Concurrently switching neutral conductor

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Frequency

50 .. 60Hz

Rated voltage

400V

Over voltage category

3

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Number of poles (total)

3

Width in number of modular spacings

3

Additional equipment possible

Pollution degree

3

Built-in depth

69mm

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.