- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Rated voltage
400V
Release characteristic
C
Number of protected poles
3
Rated insulation voltage Ui
440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10kA
Current limiting class
3
Degree of protection (IP)
IP20
Suitable for flush-mounted installation
No
Concurrently switching neutral conductor
No
Connectable conductor cross section solid-core
0 - 35mm²
Ambient temperature during operating
-25 - 55°C
Rated current
2A
Over voltage category
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6kA
Number of poles (total)
3
Rated impulse withstand voltage Uimp
4kV
Frequency
50 - 60Hz
Width in number of modular spacings
3
Pollution degree
3
Connectable conductor cross section multi-wired
0 - 25mm²
Built-in depth
69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
20kA
Additional equipment possible
Yes
Voltage type
AC
Power loss
5.4W
Explosion-proof
No
Flush-mounted installation
No
Warehouse states
Zagreb:
1 pcs
Zadar:
0 pcs
From same serie
2CDS253001R0024 | S203-C2
![Main Product Image](https://assets.aleta.hr/300x300/4a35eaf0-e062-403f-8d1d-ba65f4ae4467_optimized.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Rated voltage
400V
Release characteristic
C
Number of protected poles
3
Rated insulation voltage Ui
440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10kA
Current limiting class
3
Degree of protection (IP)
IP20
Suitable for flush-mounted installation
Concurrently switching neutral conductor
Connectable conductor cross section solid-core
0 .. 35mm²
Ambient temperature during operating
-25 .. 55°C
Rated current
2A
Over voltage category
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6kA
Number of poles (total)
3
Rated impulse withstand voltage Uimp
4kV
Frequency
50 .. 60Hz
Width in number of modular spacings
3
Pollution degree
3
Connectable conductor cross section multi-wired
0 .. 25mm²
Built-in depth
69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
20kA
Additional equipment possible
Voltage type
AC
Power loss
5.4W