![Main Product Image](https://assets.aleta.hr/415x415/20efd65e-41dc-4007-ae75-61eab5225576.webp)
![Main Product Image](https://assets.aleta.hr/415x415/20efd65e-41dc-4007-ae75-61eab5225576.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Number of poles (total)
1
Release characteristic
B
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10kA
Rated insulation voltage Ui
440V
Rated current
50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6kA
Number of protected poles
1
Voltage type
AC/DC
Current limiting class
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6kA
Width in number of modular spacings
1
Pollution degree
2
Additional equipment possible
Yes
Rated voltage
230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
10kA
Concurrently switching neutral conductor
No
Over voltage category
3
Degree of protection (IP)
IP20
Frequency
50 - 60Hz
Connectable conductor cross section multi-wired
0 - 25mm²
Suitable for flush-mounted installation
No
Ambient temperature during operating
-25 - 55°C
Connectable conductor cross section solid-core
0 - 35mm²
Built-in depth
69mm
Rated impulse withstand voltage Uimp
4kV
Warehouse states
Zagreb:
40 pcs
Zadar:
0 pcs
From same serie
2CDS251001R0505 | S201-B50
![Main Product Image](https://assets.aleta.hr/300x300/e899ccef-d378-4457-8621-3c7fc9a40a72_optimized.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Number of poles (total)
1
Release characteristic
B
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
10kA
Rated insulation voltage Ui
440V
Rated current
50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
6kA
Number of protected poles
1
Voltage type
AC/DC
Current limiting class
3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
6kA
Width in number of modular spacings
1
Pollution degree
2
Additional equipment possible
Rated voltage
230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
10kA
Concurrently switching neutral conductor
Over voltage category
3
Degree of protection (IP)
IP20
Frequency
50 .. 60Hz
Connectable conductor cross section multi-wired
0 .. 25mm²
Suitable for flush-mounted installation
Ambient temperature during operating
-25 .. 55°C
Connectable conductor cross section solid-core
0 .. 35mm²
Built-in depth
69mm
Rated impulse withstand voltage Uimp
4kV
From same serie
We use cookies to enhance your experience.