Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

No

System configuration IT

No

System configuration TN-C

No

System configuration other

No

Number of conductors (without earthing)

-

Nominal voltage DC

-V

Short-circuit breaking capacity (Isccr)

-kA

Max. continuous voltage DC

-V

Max. PV-voltage

-V

With remote signalling contact

No

Voltage protection level N-PE

1.3kV

Max. conductor cross section flexible (fine-strand)

35mm²

System configuration TN

Yes

Nominal discharge surge current (8/20)

20kA

Max. discharge surge current (8/20)

40kA

System configuration TT

Yes

Max. continuous voltage AC

280V

Integrated backup fuse

No

Voltage protection level L-N

1.3kV

System configuration TN-C-S

Yes

Voltage protection level

1.3kV

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN-S

Yes

Nominal voltage AC

230V

Category type 2

Yes

Construction size

3 modular spacing

Degree of protection (IP)

IP20

Signalling at the device

Optic


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

5095252 | V20-2+NPE-280

Main Product Image

Code

1646284

Catalog number

5095252

Type

Surge protection device for power supply systems

Manufacturer

Obo Bettermann

Serie

-

Neto WSP:

82,02

RP:102,53
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

System configuration IT

System configuration TN-C

System configuration other

Number of conductors (without earthing)

-

Nominal voltage DC

-V

Short-circuit breaking capacity (Isccr)

-kA

Max. continuous voltage DC

-V

Max. PV-voltage

-V

With remote signalling contact

Voltage protection level N-PE

1.3kV

Max. conductor cross section flexible (fine-strand)

35mm²

System configuration TN

Nominal discharge surge current (8/20)

20kA

Max. discharge surge current (8/20)

40kA

System configuration TT

Max. continuous voltage AC

280V

Integrated backup fuse

Voltage protection level L-N

1.3kV

System configuration TN-C-S

Voltage protection level

1.3kV

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration TN-S

Nominal voltage AC

230V

Category type 2

Construction size

3 modular spacing

Degree of protection (IP)

IP20

Signalling at the device

Optic

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.