Aleta.hr
Main Product Image

2CSF204001R1950 | F204AC-125/0,03

Code: 1558118

ManufacturerABB
Catalog number2CSF204001R1950
EAN code8012542941507
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
956,28 €
Neto956,28
RP1.195,35
pcs

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Rated voltage

400V

Rated current

125A

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Power loss

-W

Rated impulse withstand voltage Uimp

4kV

Mounting method

DIN rail

Leakage current type

AC

Selective protection

No

Short-time delayed tripping

No

Short-circuit breaking capacity (Icw)

1kA

Surge current capacity

0.25kA

With interlocking device

Yes

Frequency

50 Hz

Additional equipment possible

Yes

Degree of protection (IP)

IP2X

Width in number of modular spacings

4

Built-in depth

69mm

Ambient temperature during operating

-25 - 40°C

Pollution degree

2

Connectable conductor cross section multi-wired

0 - 25mm²

RAL-number (similar)

-

Connectable conductor cross section solid-core

35 - 35mm²

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CSF204001R1950 | F204AC-125/0,03

Main Product Image

Code

1558118

Catalog number

F429415

Type

Residual current circuit breaker (RCCB)

Manufacturer

ABB

Serie

-

Neto WSP:

956,28

RP:1.195,35
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Rated voltage

400V

Rated current

125A

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Power loss

-W

Rated impulse withstand voltage Uimp

4kV

Mounting method

DIN rail

Leakage current type

AC

Selective protection

Short-time delayed tripping

Short-circuit breaking capacity (Icw)

1kA

Surge current capacity

0.25kA

With interlocking device

Frequency

50 Hz

Additional equipment possible

Degree of protection (IP)

IP2X

Width in number of modular spacings

4

Built-in depth

69mm

Ambient temperature during operating

-25 .. 40°C

Pollution degree

2

Connectable conductor cross section multi-wired

0 .. 25mm²

RAL-number (similar)

-

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.